Is a PVC condensate drain up to code in San José?
Usually yes for a small drain. The California Mechanical Code and Plumbing Code allow PVC for condensate waste piping smaller than 1-1/4 inch.23 The code also sets slope, cleanouts, overflow protection and where the drain can end.1
CSLB #1050108 · Licensed, bonded and insured

The short version
What the code asks of a condensate drain
San José adopts the 2025 California Mechanical and Plumbing Codes.6 The City page adds its own termination list.1
Pick the material
PVC is fine for lines under 1-1/4 inch. The material also has to suit the pressure and temperature rating of the equipment and be approved for the liquid being discharged.2
Size the line
For air-cooling coils, the minimum is 3/4 inch up to 20 tons of refrigeration, 1 inch for 21 to 40 tons, 1-1/4 inch for 41 to 90 tons, 1-1/2 inch for 91 to 125 tons and 2 inch for 126 to 250 tons.2 Drains from single condensing appliances follow the maker's instructions.
Set the slope and corrosion rating
At least 1/8 inch per foot (1 percent), in approved corrosion-resistant material, no smaller than the equipment outlet.4
Add a cleanout
The line must be configured or provided with a cleanout so a blockage can be cleared without cutting the drain.2
Protect against overflow
Where a spill could do damage, add a float switch, a second pan with its own drain, or a second drain line.4
End it at an approved point
Use an air gap or air break to a trapped, vented receptacle, a dry well, a fixture tailpiece or a bioswale.1 Then schedule the inspection. See our inspection guide.
City termination and drywell rules
- Drywell, option 1
- At least 2 feet square and 2 feet deep, at least 3 feet from the foundation, filled with 1 inch rock or gravel, covered with building paper or plastic and 6 inches of earth or concrete. A condensate pipe of at least 3/4 inch connects indirectly to a drainpipe of at least 1-1/2 inch, by an air gap or air break at the edge of the foundation.1
- Drywell, option 2
- 24 inch grade rings, at least two rings for up to 30 tons, at least 8 feet from the foundation, with a solid concrete cover and a 6 inch layer of 1 inch rock around the bottom and sides.1
- Equipment in an attic
- The City refers to the secondary protection rules in CMC 310.2 and CPC 814.2 for equipment in an attic, furred space or dropped ceiling.1
- Always check the current code
- The City says to check the current Building, Plumbing and Mechanical codes and the manufacturer's installation instructions. Your inspector decides what is approved for your job.1
Replacing an AC or water heater? We handle the permit and the drain.
Tell us about the equipment and where the drain runs now. We pull the permit, build the drain to code and schedule the inspection through final.
- The city and the age of the house
- The equipment: AC, furnace, heat pump or water heater
- Where the unit sits and where the drain ends now
Prefer to talk? Call (408) 667-4946 or send a text. Office hours: Monday to Friday, 7 am to 3 pm.
- CSLB #1050108
- Licensed, bonded and insured
- 1-year labor warranty
- BBB A+ rating
David and Tristan, the owners, stay involved from the first walkthrough to the final check. We reply the same business day, Monday to Friday.
Is PVC allowed for an AC condensate drain in San Jose?
What size does the condensate drain need to be?
What slope does a condensate drain need?
Where can the condensate drain end in San Jose?
Do I need a second drain or overflow switch?
Sources
- 1. City of San José: Condensate Disposal Requirements (updated 04/13/2026)
- 2. California Mechanical Code 310.3: Condensate waste pipe material and sizing (2025 ed.)
- 3. California Plumbing Code 814.3: Condensate waste pipe material and sizing (2025 ed.)
- 4. California Mechanical Code 310.1, 310.2 and 310.5
- 5. California Plumbing Code 814.1, 814.2 and 814.5
- 6. San José Municipal Code 24.05.100 (adopts the 2025 California Mechanical Code) and 24.04.100 (2025 California Plumbing Code)
This page explains published code and City rules for condensate drains. The City and your inspector decide what applies to your job. Check the City page and the current codes.